| Model |
Capacity (kg) |
Safe Overload (kg) |
Output Signal (mV/V) |
Diameter (in) |
Length (in) |
Cable Length (ft) |
| 1000A-2 |
450 |
770 |
6.0 |
1.0 |
7.0 |
12 |
| 3000A-2 |
1300 |
2300 |
1.0 |
1.5 |
12.0 |
15 |
| 10000A-2 |
4500 |
7700 |
6.0 |
2.0 |
15.5 |
20 |
| 25000A-2 |
11,000 |
16,000 |
1.5 |
2.5 |
15.5 |
25 |
| 60000A-2 |
27,000 |
40,000 |
|
3.0 |
15.5 |
30 |
Applications:
» install beneath hoppers, silos, tanks & platforms in multi point configurations
» two cell usage for monorail application
Features:
» 100% waterproof, immersable or power washable
Accuracy:
» 99.9% full scale
Temperature:
» compensated -10°C to +40°C
Material:
» nickel alloy steel, 100% silicone jacket, stainless steel clamps
Cable:
» stranded 4 conductor with shielding
» custom lengths available
Input:
» excitation: 5 to 15 volts DC
Circuit:
» full wheatstone bridge, 350 ohm impedance
Series A Brackets
Series A Loadcell mounted in bracket
Some brackets may differ slightly from above, more detailed drawings are available for each model.
Only larger models have four holes in top plate. Dimension F does not apply to models with two holes in top plate.
| Model |
A Length (in) |
B Width (in) |
C (in) |
D (in) |
E (in) |
F (in) |
G (in) |
H (in) |
Total Height (in) |
| 1000A-2 |
7.0 |
8.0 |
1.5 |
4.0 |
7.8 |
n/a |
3.0 |
5.5 |
3.4 |
| 3000A-2 |
12.0 |
9.0 |
1.0 |
5.0 |
11.0 |
n/a |
3.0 |
7.0 |
4.3 |
| 10000A-2 |
15.0 |
10.5 |
4.0 |
7.0 |
12.3 |
2.5 |
3.6 |
8.0 |
5.0 |
| 25000A-2 |
16.0 |
11.8 |
2.0 |
8.0 |
12.0 |
5.0 |
5.0 |
7.8 |
7.1 |
| 60000A-2 |
17.5 |
13.5 |
2.5 |
8.5 |
11.3 |
7.5 |
7.5 |
9.5 |
9.0 |
Loadcell Lineup:


see also:
Chicken Farm Case Study